complement c4 (c4) kit Search Results


93
Elabscience Biotechnology complement 4 c4
Complement 4 C4, supplied by Elabscience Biotechnology, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/complement+c4+(c4)+kit/Rat+C4+(Complement+Component+4)+ELISA+Kit/pm41203636-113-26-46
Average 93 stars, based on 1 article reviews
complement 4 c4 - by Bioz Stars, 2026-09
93/100 stars
  Buy from Supplier

93
Cusabio c4 50 × dilution human csb e08705h cusabio china
C4 50 × Dilution Human Csb E08705h Cusabio China, supplied by Cusabio, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/complement+c4+(c4)+kit/Human+Complement+4%2CC4+ELISA+Kit/pmc09215050-96-50-55
Average 93 stars, based on 1 article reviews
c4 50 × dilution human csb e08705h cusabio china - by Bioz Stars, 2026-09
93/100 stars
  Buy from Supplier

90
Assaypro complement c4 c4a nm 007293 2 np 009224 2 720 assaypro
Complement C4 C4a Nm 007293 2 Np 009224 2 720 Assaypro, supplied by Assaypro, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/complement+c4+(c4)+kit/Human+Complement+C4+AssayMax+ELISA+Kit/us09435813-69-98-104
Average 90 stars, based on 1 article reviews
complement c4 c4a nm 007293 2 np 009224 2 720 assaypro - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

93
Cusabio complement 4
Complement 4, supplied by Cusabio, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/complement+c4+(c4)+kit/Rat+Complement+4%2CC4+ELISA+Kit/pmc12516705-96-5-15
Average 93 stars, based on 1 article reviews
complement 4 - by Bioz Stars, 2026-09
93/100 stars
  Buy from Supplier

93
Elabscience Biotechnology c4 elabscience cat e el m3020
C4 Elabscience Cat E El M3020, supplied by Elabscience Biotechnology, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/complement+c4+(c4)+kit/Mouse+C4+(Complement+Component+4)+ELISA+Kit/10__1002_slash_imt2__70027-459-6-7
Average 93 stars, based on 1 article reviews
c4 elabscience cat e el m3020 - by Bioz Stars, 2026-09
93/100 stars
  Buy from Supplier

93
Elabscience Biotechnology complement c4
Characteristics of EV-derived <t>complement</t> DEPs in patients with schizophrenia. ( A ) Comparison of C3 expression between patients with schizophrenia (SZ) and healthy controls (HC). *P = 0.039, Cohen's d = 0.78. ( B ) Comparison of <t>C4A</t> expression. *** P < 0.001, Cohen's d = 1.57. ( C ) Comparison of C4B expression. *** P < 0.001, Cohen's d = 1.24. ( D ) Comparison of C4BPA expression. ** P = 0.0029, Cohen's d = 1.17. ( E ) Comparison of C4BPB expression. * P = 0.0129, Cohen's d = 0.88. ( F ) Comparison of PROS1 expression. *** P < 0.001, Cohen's d = 1.20. Although the levels of body mass index (BMI) and diastolic blood pressure (DBP) were significantly different between patients and controls, they did not demonstrate significant correlations with the levels of extracellular vesicle (EV)-derived complement associated components within each independent group. Hence, they were not adjusted as covariates. ( G and H ) The heat map of correlation analysis between EV-derived non-differentially expressed proteins (DEPs) and DEPs in the complement network and the disease course. Significant correlation was defined as absolute R values ≥0.4 and P -value <0.05 [−log10 ( P ) > 1.3]. Pearson or Spearman correlation was used as appropriate. ( I ) Box plot of the absolute R value of correlation analysis. ** P = 0.0015, Cohen's d = 1.67. ( J – L ) Expression levels of NOE1 , KIRR3 and LMO4 mRNA in different tissues; their mRNA expression were mostly enriched in brain. Data were extracted from the Human Protein Atlas. ( M ) Heat map of linear correlation results between the EV-derived complement DEPs and brain enriched proteins of NOE1, KIRR3 and LMO4 in patients and healthy controls. The number in each box and the legend represent the R-value. * P < 0.05; ** P < 0.01; *** P < 0.001.
Complement C4, supplied by Elabscience Biotechnology, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/complement+c4+(c4)+kit/Human+C4+(Complement+Component+4)+ELISA+Kit/pmc10907082-76-5-8
Average 93 stars, based on 1 article reviews
complement c4 - by Bioz Stars, 2026-09
93/100 stars
  Buy from Supplier

93
Assaypro c4bp elisa kit
Absolute changes in the plasma levels of several proteins in female patients with metabolic syndrome after the 12-week dietary interventions analysed using an <t>ELISA</t> kit: caloric restriction (CR) or caloric restriction with protein supplementation (CRPS). Box plots represent values between the 25th and 75th percentile. The solid line within the box is the median value, and the symbol within the box is the mean value. The circles are values that are 1.5 times the interquartile range above the upper quartile and below the lower quartile. Units of raw data are ng/mL. * p < 0.05 in comparison with postintervention measurements between the groups and according to the Quade’s test with baseline measurements as covariates.
C4bp Elisa Kit, supplied by Assaypro, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/complement+c4+(c4)+kit/Human+Complement+C4-Binding+Protein+(C4BP)+AssayMax+ELISA+Kit/pmc06406984-125-32-36
Average 93 stars, based on 1 article reviews
c4bp elisa kit - by Bioz Stars, 2026-09
93/100 stars
  Buy from Supplier

90
BioSino Inc complement c3 test kit
Absolute changes in the plasma levels of several proteins in female patients with metabolic syndrome after the 12-week dietary interventions analysed using an <t>ELISA</t> kit: caloric restriction (CR) or caloric restriction with protein supplementation (CRPS). Box plots represent values between the 25th and 75th percentile. The solid line within the box is the median value, and the symbol within the box is the mean value. The circles are values that are 1.5 times the interquartile range above the upper quartile and below the lower quartile. Units of raw data are ng/mL. * p < 0.05 in comparison with postintervention measurements between the groups and according to the Quade’s test with baseline measurements as covariates.
Complement C3 Test Kit, supplied by BioSino Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/complement+c4+(c4)+kit/complement+c4+test+kit/pmc10371818-116-69-88
Average 90 stars, based on 1 article reviews
complement c3 test kit - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

94
Assaypro human complement c4 assaymax elisa kit
Absolute changes in the plasma levels of several proteins in female patients with metabolic syndrome after the 12-week dietary interventions analysed using an <t>ELISA</t> kit: caloric restriction (CR) or caloric restriction with protein supplementation (CRPS). Box plots represent values between the 25th and 75th percentile. The solid line within the box is the median value, and the symbol within the box is the mean value. The circles are values that are 1.5 times the interquartile range above the upper quartile and below the lower quartile. Units of raw data are ng/mL. * p < 0.05 in comparison with postintervention measurements between the groups and according to the Quade’s test with baseline measurements as covariates.
Human Complement C4 Assaymax Elisa Kit, supplied by Assaypro, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/complement+c4+(c4)+kit/Human+Complement+C4+AssayMax+ELISA+Kit/assaypro___ec3202-7
Average 94 stars, based on 1 article reviews
human complement c4 assaymax elisa kit - by Bioz Stars, 2026-09
94/100 stars
  Buy from Supplier

92
Bio-Techne corporation human complement c4 elisa kit (colorimetric)
Absolute changes in the plasma levels of several proteins in female patients with metabolic syndrome after the 12-week dietary interventions analysed using an <t>ELISA</t> kit: caloric restriction (CR) or caloric restriction with protein supplementation (CRPS). Box plots represent values between the 25th and 75th percentile. The solid line within the box is the median value, and the symbol within the box is the mean value. The circles are values that are 1.5 times the interquartile range above the upper quartile and below the lower quartile. Units of raw data are ng/mL. * p < 0.05 in comparison with postintervention measurements between the groups and according to the Quade’s test with baseline measurements as covariates.
Human Complement C4 Elisa Kit (Colorimetric), supplied by Bio-Techne corporation, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/complement+c4+(c4)+kit/Human+Complement+C4+ELISA+Kit+(Colorimetric)/bio-techne+corporation___nbp2-60619
Average 92 stars, based on 1 article reviews
human complement c4 elisa kit (colorimetric) - by Bioz Stars, 2026-09
92/100 stars
  Buy from Supplier

Image Search Results


Characteristics of EV-derived complement DEPs in patients with schizophrenia. ( A ) Comparison of C3 expression between patients with schizophrenia (SZ) and healthy controls (HC). *P = 0.039, Cohen's d = 0.78. ( B ) Comparison of C4A expression. *** P < 0.001, Cohen's d = 1.57. ( C ) Comparison of C4B expression. *** P < 0.001, Cohen's d = 1.24. ( D ) Comparison of C4BPA expression. ** P = 0.0029, Cohen's d = 1.17. ( E ) Comparison of C4BPB expression. * P = 0.0129, Cohen's d = 0.88. ( F ) Comparison of PROS1 expression. *** P < 0.001, Cohen's d = 1.20. Although the levels of body mass index (BMI) and diastolic blood pressure (DBP) were significantly different between patients and controls, they did not demonstrate significant correlations with the levels of extracellular vesicle (EV)-derived complement associated components within each independent group. Hence, they were not adjusted as covariates. ( G and H ) The heat map of correlation analysis between EV-derived non-differentially expressed proteins (DEPs) and DEPs in the complement network and the disease course. Significant correlation was defined as absolute R values ≥0.4 and P -value <0.05 [−log10 ( P ) > 1.3]. Pearson or Spearman correlation was used as appropriate. ( I ) Box plot of the absolute R value of correlation analysis. ** P = 0.0015, Cohen's d = 1.67. ( J – L ) Expression levels of NOE1 , KIRR3 and LMO4 mRNA in different tissues; their mRNA expression were mostly enriched in brain. Data were extracted from the Human Protein Atlas. ( M ) Heat map of linear correlation results between the EV-derived complement DEPs and brain enriched proteins of NOE1, KIRR3 and LMO4 in patients and healthy controls. The number in each box and the legend represent the R-value. * P < 0.05; ** P < 0.01; *** P < 0.001.

Journal: Brain

Article Title: Extracellular vesicle biomarkers for complement dysfunction in schizophrenia

doi: 10.1093/brain/awad341

Figure Lengend Snippet: Characteristics of EV-derived complement DEPs in patients with schizophrenia. ( A ) Comparison of C3 expression between patients with schizophrenia (SZ) and healthy controls (HC). *P = 0.039, Cohen's d = 0.78. ( B ) Comparison of C4A expression. *** P < 0.001, Cohen's d = 1.57. ( C ) Comparison of C4B expression. *** P < 0.001, Cohen's d = 1.24. ( D ) Comparison of C4BPA expression. ** P = 0.0029, Cohen's d = 1.17. ( E ) Comparison of C4BPB expression. * P = 0.0129, Cohen's d = 0.88. ( F ) Comparison of PROS1 expression. *** P < 0.001, Cohen's d = 1.20. Although the levels of body mass index (BMI) and diastolic blood pressure (DBP) were significantly different between patients and controls, they did not demonstrate significant correlations with the levels of extracellular vesicle (EV)-derived complement associated components within each independent group. Hence, they were not adjusted as covariates. ( G and H ) The heat map of correlation analysis between EV-derived non-differentially expressed proteins (DEPs) and DEPs in the complement network and the disease course. Significant correlation was defined as absolute R values ≥0.4 and P -value <0.05 [−log10 ( P ) > 1.3]. Pearson or Spearman correlation was used as appropriate. ( I ) Box plot of the absolute R value of correlation analysis. ** P = 0.0015, Cohen's d = 1.67. ( J – L ) Expression levels of NOE1 , KIRR3 and LMO4 mRNA in different tissues; their mRNA expression were mostly enriched in brain. Data were extracted from the Human Protein Atlas. ( M ) Heat map of linear correlation results between the EV-derived complement DEPs and brain enriched proteins of NOE1, KIRR3 and LMO4 in patients and healthy controls. The number in each box and the legend represent the R-value. * P < 0.05; ** P < 0.01; *** P < 0.001.

Article Snippet: Complement C3 (C3, Cloud-Clone, SEA861Hu), Complement C4 (C4, Elabscience, E-EL-H6027), C4b-binding protein alpha chain (C4BPA, Cloud-Clone, SEB620Hu) and vitamin K-dependent protein S (PROS1, Cloud-Clone, SEB971Hu) were analysed.

Techniques: Derivative Assay, Comparison, Expressing

Potential biomarkers validated in EVs in patients with schizophrenia and healthy controls. The concentration of extracellular vesicle (EV)-derived complement differentially expressed proteins were detected by proteomics (Set 1) and Mesoscale Discovery technology (Set 2). ( A and B ) C3 amount in EVs. Set 1: * P = 0.039, Cohen's d = 0.78. Set 2: ** P < 0.001, Cohen's d = 1.13. ( C and D ) C4 amount in EVs. Set 1: *** P < 0.001, Cohen's d = 1.36. C4 intensity was the combination of C4A and C4B intensity. Set 2: * P = 0.019, Cohen's d = 0.67. ( E and F ) C4BPA amount in EVs. Set 1: ** P = 0.003, Cohen's d = 1.17. Set 2: *** P < 0.001, Cohen's d = 2.04. ( G and H ) PROS1 amount in EVs. Set 1: *** P < 0.001, Cohen's d = 1.20. Set 2: ** P = 0.0023, Cohen's d = 0.90. Although the levels of body mass index or diastolic blood pressure were significantly different between patients (SZ) and controls (HC), they did not demonstrate significant correlations with the levels of complement-associated components within each independent group. Hence, they were not adjusted as covariates. ( I – L ) Western blot analysis of the activation of EV-derived Complement C3 and C4. Neoepitope-specific antibodies of C3a and C4a were used. Human serum purified proteins of C3a des Arg and C4a des Arg were used as the positive controls. The last lane of each membrane was the positive control. n = 11 for each group. SZ = schizophrenia; HC = healthy controls.

Journal: Brain

Article Title: Extracellular vesicle biomarkers for complement dysfunction in schizophrenia

doi: 10.1093/brain/awad341

Figure Lengend Snippet: Potential biomarkers validated in EVs in patients with schizophrenia and healthy controls. The concentration of extracellular vesicle (EV)-derived complement differentially expressed proteins were detected by proteomics (Set 1) and Mesoscale Discovery technology (Set 2). ( A and B ) C3 amount in EVs. Set 1: * P = 0.039, Cohen's d = 0.78. Set 2: ** P < 0.001, Cohen's d = 1.13. ( C and D ) C4 amount in EVs. Set 1: *** P < 0.001, Cohen's d = 1.36. C4 intensity was the combination of C4A and C4B intensity. Set 2: * P = 0.019, Cohen's d = 0.67. ( E and F ) C4BPA amount in EVs. Set 1: ** P = 0.003, Cohen's d = 1.17. Set 2: *** P < 0.001, Cohen's d = 2.04. ( G and H ) PROS1 amount in EVs. Set 1: *** P < 0.001, Cohen's d = 1.20. Set 2: ** P = 0.0023, Cohen's d = 0.90. Although the levels of body mass index or diastolic blood pressure were significantly different between patients (SZ) and controls (HC), they did not demonstrate significant correlations with the levels of complement-associated components within each independent group. Hence, they were not adjusted as covariates. ( I – L ) Western blot analysis of the activation of EV-derived Complement C3 and C4. Neoepitope-specific antibodies of C3a and C4a were used. Human serum purified proteins of C3a des Arg and C4a des Arg were used as the positive controls. The last lane of each membrane was the positive control. n = 11 for each group. SZ = schizophrenia; HC = healthy controls.

Article Snippet: Complement C3 (C3, Cloud-Clone, SEA861Hu), Complement C4 (C4, Elabscience, E-EL-H6027), C4b-binding protein alpha chain (C4BPA, Cloud-Clone, SEB620Hu) and vitamin K-dependent protein S (PROS1, Cloud-Clone, SEB971Hu) were analysed.

Techniques: Concentration Assay, Derivative Assay, Western Blot, Activation Assay, Purification, Membrane, Positive Control

Potential biomarkers validated in plasma in patients with schizophrenia and healthy controls. The concentration of complement differentially expressed proteins in plasma were detected by ELISA. ( A and B ) Plasma concentration of C3. Set 1: P = 0.16, Cohen's d = 0.43. Set 2: P = 0.22, Cohen's d = 0.35. ( C and D ) Plasma concentration of C4. Set 1: P = 0.76, Cohen's d = 0.0005. Set 2: P = 0.72, Cohen's d = 0.098. ( E and F ) Plasma concentration of C4BPA. Set 1: P = 0.25, Cohen's d = 0.35. Set 2: * P = 0.03, Cohen's d = 0.27. ( G and H ) Plasma concentration of PROS1. Set 1: ** P = 0.001, Cohen's d = 1.11. Set 2: P = 0.87, Cohen's d = 0.02. Although the levels of body mass index or diastolic blood pressure were significantly different between patients and controls, they did not demonstrate significant correlations with the levels of complement associated components within each independent group. Consequently, they were not adjusted as covariates. SZ = schizophrenia; HC = healthy controls; n.s. = not significant.

Journal: Brain

Article Title: Extracellular vesicle biomarkers for complement dysfunction in schizophrenia

doi: 10.1093/brain/awad341

Figure Lengend Snippet: Potential biomarkers validated in plasma in patients with schizophrenia and healthy controls. The concentration of complement differentially expressed proteins in plasma were detected by ELISA. ( A and B ) Plasma concentration of C3. Set 1: P = 0.16, Cohen's d = 0.43. Set 2: P = 0.22, Cohen's d = 0.35. ( C and D ) Plasma concentration of C4. Set 1: P = 0.76, Cohen's d = 0.0005. Set 2: P = 0.72, Cohen's d = 0.098. ( E and F ) Plasma concentration of C4BPA. Set 1: P = 0.25, Cohen's d = 0.35. Set 2: * P = 0.03, Cohen's d = 0.27. ( G and H ) Plasma concentration of PROS1. Set 1: ** P = 0.001, Cohen's d = 1.11. Set 2: P = 0.87, Cohen's d = 0.02. Although the levels of body mass index or diastolic blood pressure were significantly different between patients and controls, they did not demonstrate significant correlations with the levels of complement associated components within each independent group. Consequently, they were not adjusted as covariates. SZ = schizophrenia; HC = healthy controls; n.s. = not significant.

Article Snippet: Complement C3 (C3, Cloud-Clone, SEA861Hu), Complement C4 (C4, Elabscience, E-EL-H6027), C4b-binding protein alpha chain (C4BPA, Cloud-Clone, SEB620Hu) and vitamin K-dependent protein S (PROS1, Cloud-Clone, SEB971Hu) were analysed.

Techniques: Clinical Proteomics, Concentration Assay, Enzyme-linked Immunosorbent Assay

Absolute changes in the plasma levels of several proteins in female patients with metabolic syndrome after the 12-week dietary interventions analysed using an ELISA kit: caloric restriction (CR) or caloric restriction with protein supplementation (CRPS). Box plots represent values between the 25th and 75th percentile. The solid line within the box is the median value, and the symbol within the box is the mean value. The circles are values that are 1.5 times the interquartile range above the upper quartile and below the lower quartile. Units of raw data are ng/mL. * p < 0.05 in comparison with postintervention measurements between the groups and according to the Quade’s test with baseline measurements as covariates.

Journal: Journal of Clinical Medicine

Article Title: Effects of Caloric Restriction with Protein Supplementation on Plasma Protein Profiles in Middle-Aged Women with Metabolic Syndrome—A Preliminary Open Study

doi: 10.3390/jcm8020195

Figure Lengend Snippet: Absolute changes in the plasma levels of several proteins in female patients with metabolic syndrome after the 12-week dietary interventions analysed using an ELISA kit: caloric restriction (CR) or caloric restriction with protein supplementation (CRPS). Box plots represent values between the 25th and 75th percentile. The solid line within the box is the median value, and the symbol within the box is the mean value. The circles are values that are 1.5 times the interquartile range above the upper quartile and below the lower quartile. Units of raw data are ng/mL. * p < 0.05 in comparison with postintervention measurements between the groups and according to the Quade’s test with baseline measurements as covariates.

Article Snippet: Commercial available plasma C4b-binding protein (C4BP), complement component C6 (C6), complement component C8 gamma chain (C8G), and vitamin K–dependent protein S (PROS) were respectively measured using the following commercial ELISA kits: (1) C4BP ELISA kit (#EC2202-1, Assaypro, St. Charles, MO, USA); (2) C6 ELISA kit (#EC6101-1, Assaypro, St. Charles, MO, USA); (3) C8G ELISA kit (#EC8120-1, Assaypro, St. Charles, MO, USA); and (4) PROS ELISA kit (#AB190808, Abcam, Cambridge, UK).

Techniques: Clinical Proteomics, Enzyme-linked Immunosorbent Assay, Comparison

Heat maps showing different baseline and postintervention protein plasma levels. A significant correlation was observed with the selected increment clinical variables between baseline and postintervention in the CR ( A ) and CRPS ( B ) groups. The left red–blue scale heatmaps show the estimates of Spearman’s correlation coefficients, whereas the right yellow-scale heat maps show the p -values for the same protein–clinical variable pairs. AG: android/gynoid fat ratio, ALB: albumin, TBF: total body fat, BMI: body mass index, CRP: C-reactive protein, FBG: fasting blood glucose, HOMA: homeostatic model assessment for insulin resistance, IL6: interleukin 6, LDL-C: low-density lipoprotein cholesterol, MONO: mononuclear, NEU: neutrophil, PLA: platelet, QUICKI: quantitative insulin sensitivity check index, TC: total cholesterol, WBC: white blood cell, A2M: alpha-2-macroglobulin, C1RL: Complement C1r subcomponent–like protein, C4BPA: C4b-binding protein alpha chain, C6: complement component C6, C8G: complement component C8 gamma chain, Protein S: vitamin K-dependent protein S, CR: caloric restriction, CRPS: caloric restriction with protein supplementation.

Journal: Journal of Clinical Medicine

Article Title: Effects of Caloric Restriction with Protein Supplementation on Plasma Protein Profiles in Middle-Aged Women with Metabolic Syndrome—A Preliminary Open Study

doi: 10.3390/jcm8020195

Figure Lengend Snippet: Heat maps showing different baseline and postintervention protein plasma levels. A significant correlation was observed with the selected increment clinical variables between baseline and postintervention in the CR ( A ) and CRPS ( B ) groups. The left red–blue scale heatmaps show the estimates of Spearman’s correlation coefficients, whereas the right yellow-scale heat maps show the p -values for the same protein–clinical variable pairs. AG: android/gynoid fat ratio, ALB: albumin, TBF: total body fat, BMI: body mass index, CRP: C-reactive protein, FBG: fasting blood glucose, HOMA: homeostatic model assessment for insulin resistance, IL6: interleukin 6, LDL-C: low-density lipoprotein cholesterol, MONO: mononuclear, NEU: neutrophil, PLA: platelet, QUICKI: quantitative insulin sensitivity check index, TC: total cholesterol, WBC: white blood cell, A2M: alpha-2-macroglobulin, C1RL: Complement C1r subcomponent–like protein, C4BPA: C4b-binding protein alpha chain, C6: complement component C6, C8G: complement component C8 gamma chain, Protein S: vitamin K-dependent protein S, CR: caloric restriction, CRPS: caloric restriction with protein supplementation.

Article Snippet: Commercial available plasma C4b-binding protein (C4BP), complement component C6 (C6), complement component C8 gamma chain (C8G), and vitamin K–dependent protein S (PROS) were respectively measured using the following commercial ELISA kits: (1) C4BP ELISA kit (#EC2202-1, Assaypro, St. Charles, MO, USA); (2) C6 ELISA kit (#EC6101-1, Assaypro, St. Charles, MO, USA); (3) C8G ELISA kit (#EC8120-1, Assaypro, St. Charles, MO, USA); and (4) PROS ELISA kit (#AB190808, Abcam, Cambridge, UK).

Techniques: Clinical Proteomics, Binding Assay